Gozney Master 100 x 100 Manual - V1.8 - Flipbook - Page 13
OPTION 2 - CANOPY
!
!
!
!
WARNING: OVEN SHOULD
NEVER BE DIRECTLY
CONNECTED TO A CANOPY
EXTRACTION SYSTEM. ALWAYS
ADHERE TO CLEARANCES FROM
COMBUSTIBLES
WARNING: VENTING OPTION 2
IS FOR A GAS BURNING OVEN
ONLY. NEVER BURN WOOD OR
ANY OTHER SOLID FUELS WHEN
EXTRACTING WITH A CANOPY.
WARNING: ALWAYS ENSURE
THAT A CARBON MONOXIDE
MONITOR IS FITTED WITHIN A
SAFE DISTANCE OF THE OVEN.
WARNING: ENSURE THAT
REGULAR INSPECTION OF
THE EXTRACTION FILTER
IS MAINTAINED. BUILD UP
OF CREOSOTE CAN CAUSE
BLOCKAGES AND RISK OF FIRE
It is highly recommended that a sign is placed within close
proximity to warn users never to burn wood in the oven when
extracting with a canopy. Burning wood without the use of a
specialist twin walled flue system can cause breakdown, creosote
build up, melting of the system, and ultimately result in property
damage, injury and in some cases, death.
Dimensions of the canopy must be sufficient for the entirety of
the equipment it is serving, including the oven.
Unless restricted by walls, the dimensions of the canopy must
always exceed the area of the oven mouth and flue terminal
by a minimum of 250mm on each free side, and by 250mm at
the front and rear. These dimensions refer to the inside of the
condensation or stiffening panel / air intake channel of the
canopy.
Gozney Ovens suggest that an extraction canopy is positioned at
a distance of 350mm from the top of the oven dome. Emissions
will be hot when leaving the oven and positioning the extraction
hood at the correct distance from the where emissions exit
is of vital importance. Positioning the canopy closer than
recommended can cause heat damage to the canopy and a
potential risk of fire, whilst positioning the extraction too far away
from the oven is likely to compromise on the canopy’s ability to
extract emissions effectively.
EXCESSIVE VENTILATION FROM OVER
HEAD CANOPIES
In the event that the overhead canopy is extracting too vigorously
it can effect the gas burner’s performance and on occasion,
remove air too quickly from the oven and cause excessive heat
loss. Always check with your extraction provider if you suspect
the canopy is over or under performing.