I-Wood Denmark - Brochure - English - Catalog - Page 23
Fire safety for
Basic, Medio+ and Pro+
F I RE
RE Q U I RE M E N T S
We’ve taken a stand – and that’s why you can safely invite nature inside with
I-Wood Denmark®. Fire performance is a crucial area, and why it’s important
for us to be able to document approved use of our panels.
I-Wood Denmark® has been subjected to a number of tests on our standard
panels. I-Wood Denmark® Basic, Medio+ and Pro+ (ordinary MDF) have been
tested in accordance with EN 13823, which proves that they achieve a minimum
of a D-s2, d2 (class 2 cladding), which is the requirement for ceiling and wall
cladding in the home.
TESTED
S T RU C T U RE S :
10 mm plaster
22x95 mm batten board
cc. 600 mm
45x95 mm batten board
cc. 600 mm
45 mm insulation
(closed cavity)
I-Wood PRO+ (16 mm)
D-s1,d0
I-Wood PRO+ (16 mm)
Test results in progress
22 mm
(open cavity)
I-Wood PRO+ (16 mm)
Test results in progress
Directly on plaster
If you have specific fire requirements or questions, please contact us.
22