LIT-AT100 AIMCO Master Catalog rev 03-01-22 low res - Catalog - Page 74
Fixtured F-Series Nutrunners
Main Unit UEC-F300MII
Controls up to 31 spindle units and directs fastening
Spindle units UEC-F024H & UEC-F060H
minus UEC-MKB
UEC-F024H with optional UEC-MKB
display unit
1
10
2
3
1
2
4
2
3
8
5
9
4
7
6
5
8
6
7
1
1 Power Socket
AC100~220V single phase
2 External Input/Output Connector
PLC1: input signal connector for control signal input (fixed allocation)
PLC2: output signal connector for judgement result and status
output (free allocation)
3 Serial Port (Data Input Connector)
RS232C DATA-IN accepts serial numbers, etc. provided by
external equipment such as a barcode reader then outputs
tightening data together with serial numbers
4 Serial Port (Data Output Connector)
RS232C PRINTER outputs tightening result data to your printer
(free format)
5 Serial Port (Data Output Connector)
RS232C PLC outputs tightening result data to PLC (free format)
6 Serial Port (Data Output Connector)
RS485 outputs tightening result data to an external exclusive
display unit
7 PC Connector
RS232C for communication with a PC
1 Status Change Switch
RUN/BYPASS change switch
RUN: Operation possible status
BYPASS: Non-operation status
2 External Communication Device
RS485 connector
3 Resolver Connector
Tool and resolver connection
4 MON Connector (Monitor Output)
Analog torque electric pressure and angle pulse
output
5 T/D Connector
Tools torque sensor connection
6 I/O Connector
External input and output control connection
7 MOTOR Connector
Connection with tools magnet motor
8 AC IN Connector
AC200V~220V 3-phase power socket
8 Spindle-to-Spindle Communication Connector
RS485 for internal spindle unit to spindle unit communications
9 Manual Switches
RESET, START, REVERSE and CAL
10 LED Display
POWER, M RUN, ACCEPT, REJECT and ALARM
74
Visit our website www.aimco-global.com
1 Manual Operation Switches
START: manual start switch
REVERSE: Manual reverse switch
CAL: Manual calibration switch
RESET: Manual reset switch
2 Data Display Operation Switch
MODE switch
SET switch
DATA UP switch
DATA DOWN switch
NOTE: Display unit (UEC-MKB) is an option