LIT-AT100 AIMCO Master Catalog rev 03-01-22 low res - Catalog - Page 71
Uryu Controllers
URYU CONTROLLER SPECIFICATIONS
UEC-4800 (A) (TP) (TPA)
UEC-5500
DC500V over 10MΩ
Insulation Protection
Approx. 30VA
Approx. 50VA
Approx. 3.6 kg
Weight
Dimensions
265(d) x 222(w) x 120(h)
240(d) x 270(w) x 115(h)
• PC (with setup software)
• UEC-4800/4800A: Manual Input on Front
LCD Panel
• UEC-4800TP/TPA: Manual Input on Front
Touch Panel
Torque Resolution ±2048 (12-Bit A/D)
Display
UEC-4800/4800A
• LCD: 20 characters x 4 lines
• Contents: Work No., Fastening Countdown
No., Fastening Time, Pulse No.
• 1-digit digital display (DPM): Work No.
• 4-digit digital display (DPM): Torque
UEC-4800TP/TPA
• 320 x 240 dot, 25 characters x 15 lines
LED
Approx. 30VA
Approx. 35VA
Approx. 11.30 kg
Approx. 2.9 kg
265(d) x 222(w) x 200(h)
254(d) × 233.5(w) × 106(h)
(with antenna)
Torque Control + Angle Monitoring
+ Fastening Counter
Torque Monitoring/Control + Fastening Counter
Main Functions
Parameter Setup
UCC-100Z
50/60 Hz
Power Frequency
Power Consumption
UECP-4810 (A)
AC100~240V ±10%
Power Supply
• PC (with setup software)
• Removable key pad
• PC (with setup software)
• Manual Input on front LCD Panel
Torque Resolution ±2048 (12-Bit A/D)
• 4-digit digital display: Torque
• 2-digit digital display: Fastening
Countdown
• 1-digit digital display (small) x 4:
Work No.
• 1-digit digital display (large): x 4:
Spindle No.
Torque Resolution ±2048 (12-Bit A/D)
• LCD: 20 characters x 4 lines
• Contents: Work No., Bolt Count
No., Tightening Time, Pulse
Blow No.
• 1-digit digital display (DPM): Work
No. displayed
• 4-digit digital display (DPM):
Torque reading displayed
COUNT Lamp: OK (Green), NOK (Red)
TORQUE Lamp: LOW (Yellow), OK (Green), HIGH (Red)
Torque Resolution ±2048 (12Bit A/D)
• LCD: 20 Characters x 8 lines
• Contents: Work No., Fastening
Countdown, Fastening Time,
Pulse No., Angle, Error message
FASTENING Lamp: LOW (Yellow),
OK (Green), HIGH (Red)
Input Terminal
Signal
• Operation Voltage/Current: DC24V/approx.
10mA
• 6 terminals (free format), VALVE
• Drive by Electric Current Input
(photo coupler insulation)
• Voltage: DC24V
• Insulation Resistance: 4.7KΩ
• 12 terminals (free format), VALVE,
+24V
• Operation Voltage/Current: DC24V, approx. 10mA
• 6 terminals (programmable). Note: Contact input necessary
Output Terminal
Signal
• Contact Capacity: AC:125V, 0.3A, DC:30V, 1A
• 6 terminals (free format), VALVE
• Contact Capacity: AC:125V, 0.3A,
DC:30V, 1A
• 8 terminals (free format), VALVE, +24
• Contact Capacity: DC 30V, 1A
• 6 terminals (programmable),
VALVE
Visit our website www.aimco-global.com
• Contact Capacity: DC30V, 1A
• 6 Terminals (free format)
71