Catalogue - Mila 2023 - Flipbook - Page 58
56
AIRWAY SAMPLING
Tracheal Wash & Bronchoalveolar Lavage (BAL) – Small Animal
Blind Method (Tube through Sterile Endotracheal Tube)
• R adiopaque Pink Stripe
• R ounded, closed tip with e yelets.
• S mooth, polished surface inside and out.
•C
entimeter markings on 8Fr sizes for pr ecise depth placement.
• Does not completely obstruct the ET tube and allo
ws some space for v entilation.
MIL
A
Use optional adapter, Item #SC15MM (see page 59),
to ventilate while obtaining sample.
1
2
SC15MM
3
4
5
6
7
8
9
10
Connect to oxygen.
DESCRIPTION
3.5Fr x 40cm (16in)
5Fr x 40cm (16in)
8Fr x 55cm (22in)
8Fr x 108cm (42in)
ITEM #
PP316
PP516
PP822
PP842
FITS STERILE ET TUBE SIZES
2.0mm ID, up to 16.5cm in length
2.5 - 4.5mm ID, up to 27cm in length
5.0 - 10.0mm ID, up to 38.5cm in length
10.0 - 11.0mm ID, up to 57.5cm in length
STERILE ET TUBE ITEM #*
ETC20
ETC25R-ETC45R
ETC50R-ETC100R
N/A
*Sterile Endotracheal Tubes on page 58.
Transtracheal Technique:
Medium to Large Dogs
Endoscopic Guided BAL:
Small and Large Animal
Catheter-o ver-needle insertion method. The semi-rigid
flushing catheter has a stiffening stylet and luer adapter
. The
flushing catheter is pack aged in a pr otectiv e slee ve to allo w
handling without a glo ve.
Single lumen catheter with female luer lock for medica
tion deliv ery and sampling at an y endoscope accessible
site. To maintain sterility during placement,these sets
contain a w ater soluble plug in the distal end.
-
Catheter-Over-Needle
Introducer
Flushing/Sampling
Catheter
DESCRIPTION
ITEM #
Medium Sized Dog - 16Ga x 41cm (16in)
flushing catheter with 14Ga introducerTW1616
Large Dog - 16Ga x 70cm (28in)
flushing catheter with 14Ga introducerTW1628
Cytobrush
Collects tissue samples fr om the br onchi and/or upper/
lower GI tr acts for the diagnosis of suspected pathology in
the airw ay. See page 57 for additional information.
DESCRIPTION
SCOPE CHANNEL SIZE
ITEM #
2.3mm OD x 190cm (76in)
2.5mm EDC190
1.8mm OD x 200cm (79in)
2.0mm EDC200
2.3mm OD x 220cm (88in)
2.5mm EDC220
2.3mm OD x 400cm (160in)
2.5mmEDC400
Two and three lumen sampling catheters enable a
sterile specimen r etrie val via an endoscope . To maintain
sterility during placement, these sets contain a gly
col plug
in the outer catheter . Once placed, the inner catheter is
advanced for r etrie val of the sterile specimen.
DESCRIPTION
SCOPE CHANNEL SIZE
Two stage catheter
1.8mm x 190cm (76in)
2.0mm
Two stage catheter
1.8mm x 250cm (100in)
2.0mm
Triple stage catheter
2.3mm x 190cm (76in)
2.5mm
888-MILA-INT
ITEM #
EMAC700
EMAC700L
EMAC800