Catalogue - Mila 2023 - Flipbook - Page 61
59
Airway/ET Tube
Exchange Catheter
Atomizer/Throat Sprayer
• I ntended for uncomplicated atr aumatic
endotr acheal tube e xchange .
•U
seful for o xygenating during fluor oscopy.
• 1 5mm adapter for tempor ary o xygen deliv ery,
NOT for v entilating the patient.
• 1 5mm adapter is r emoved to slide ET tubes
out and in.
•C
entimeter markings for alignment with
endotr acheal tube markings.
•P
olished, atr aumatic , open-ended catheter
with side holes.
DESCRIPTION
ITEM #
8Fr x 80cm (32in)
ETE0880
10Fr x 80cm (32in)
ETE1080
10Fr x 150cm (60in) ETE10150
15Fr x 80cm (32in)
ETE1580
Deliv er topical anesthetic to the nose , thr oat,
hypopharynx, v ocal cor ds, larynx and tr achea
prior to airw ay manipulation such as intubation,
endoscop y, rhinoscop y and soft palate e xam. The
benefit is a r educed gag and sensation, r educed pulse
and blood pr essur e response to intubation.
•A
tomize medication into a fine mist of particles
50-80 micr ons.
• 15Fr (4.7mm) tip x 6.5 inch (15cm) malleable
,
conformable tube for tar geted deposition of
medication.
• 5cc syringe is r ecommended for accur ate dosing
and pr oper pr essur e.
• Priming v olume is 0.2ml.
• Use a 3ml syringe for a minimum for ecast distance
of 100mm upon e xiting the spr ayer tip under
25Kpa pr essur e to form an ar ea of diameter of no
less than 7 0mm.
ITEM #
5380
“The device makes endoscopy work
within the nasal cavity, soft palate, larynx
and pharnyx much easier by distributing
a fine mist of lidocaine or lidocaine/
phenylephrine.”
“We also use the device to distribute
same mixture in hard to reach surgical
areas such as otic canals, wound flaps,
urogenital tracts, and to atomize topical local anesthetics and
hemostatic agents to bleeding tumors and derm biopsy sites.”
Andrea Looney, DVM, DACVAA, DACVSMR
Anesthesia Services, IVG Hospitals, Woburn, MA
★
N
E
W
Double Swivel Tracheal Tube Connector with Capped Port, 15mm
Designed to facilitate intr oduction of fiber optic
bronchoscope during mechanical v entilation.
• S ilicone port with cap allo ws easy passage of fiber
optic scope for br onchoscop y.
•A
llo ws for suction catheter without disconnecting
from ventilator .
•M
aintains seal ar ound scope during br onchoscop y
procedur e. Seal accepts br onchoscope diameters
from 3.4 to 5.9mm.
• 360 º Double Swiv el Featur e: Both the male and
female 15mm connectors allo w gr eater patient
maneuv erability betw een endotr acheal tube and
anesthesia cir cuit.
ITEM #
Port for Bronchoscope
Connect to
Anesthesia
Circuit
Connect to Endotracheal Tube
SC15MM
www.milaint.com