Catalogue - Mila 2023 - Flipbook - Page 76
74
★
N
E
W
BLOOD COLLECTION AND DELIVERY
Small and Large Animal Blood Filtration & Administration Sets
with 200 Micron Filter
Ideal for pr eparation and deliv ery of aliquots of whole blood, r ed cells and platelets, cellular components and
fresh-frozen plasma for tr ansfusion and autotr ansfusion.
See 2020 publication in Veterinary Record Case Reports: “Traumatic haemothorax in a dog managed without surgery using a guidewire-inserted
chest tube and a single closed system for collection and administration of autotransfusion.” Miller, Victoria; Pigott, Armi
High-Flow Blood Administration
•L
ar ge bore tubing for HIGH FLO W blood
administr ation.
• Ideal in lar ge animal applications to filter and
administer blood fr om a bag.
• Set includes spik e, drip chamber , tubing, r oller
clamp, 200 micr on blood filter , needle-fr ee injection
port and SPINNER luer lock. T otal length 203cm
(80 inches).
• Gravity flo w r ates (not pr essurized)using
simulated blood:
No Catheter = 710ml/minute
14Ga x 5.25 inch Catheter = 180ml/minute
12Ga x 5.25 inch Catheter = 375ml/minute
10Ga x 5.25 inch Catheter = 475ml/minute
• Priming Volume is 36ml.
• Filtr ation Ar ea: 16 squar e centimeters
Volume limit depends on a v ariety of factors such
as blood density and tr ansfusion pr essur e.
• Flow r ates can be incr eased using pr essurization kit,
item number AF48 (on pr evious page).
• Item # BF200-2
Syringe Administration
• Standar d bore tubing.
• Ideal to filter and administer blood fr om a syringe .
• Set includes female luer , tubing, 200 micr on blood
filter, pinch clamp and SPINNER luer lock.T otal
length 43cm (17 inches).
• Priming Volume is 4ml.
• Filtr ation Ar ea: 16 squar e centimeters V olume
limit depends on a v ariety of factors such as blood
density and tr ansfusion pr essur e.
• Item # BF200-3
BF200-3
BF200-2
Bag Administration
Spike
to Bag
AF48
Check
Valve
Air in
to Bag
Blood
out
BF200-2
To Patient
Items used to pressurize bag.
Air
Filter
• Standar d bore tubing.
• Ideal for use when needing to dr aw and filter
blood fr om a bag into a syringe . Connect to MILA
Automatic 3-w ay set to mak e a completely closed,
automatic , RAPID deliv ery system. Gr eat for
autotr ansfusion. R efer to Pigott study (link to article
below). See page 75 for details.
• Set includes non-v ented spik e, tubing, pinch clamp,
200 micr on blood filter and female luer lock. T otal
length 47cm (18 inches).
• Priming Volume is 3ml.
• Filtr ation Ar ea: 16 squar e centimeters
Volume limit depends on a v ariety of factors such
as blood density and tr ansfusion pr essur e.
• Item # BF200-4
BF200-4
BF200-4
175590
Pigott study:https://vetrecordcasereports.bmj.com/content/8/3/e001142
888-MILA-INT