iM3 Catalogue - Español - Flipbook - Página 107
based on
iM3 Small Animal Dental Equipment
Precision Imaging
Specifically conceived for digital X-ray imaging, the constant
potential tube head combined with the smallest focal spot available
for intraoral imaging (0.4 mm) guarantees consistently sharp images.
Revolution 4DC Multi-Mode
Totally automatic choice of the most appropriate combination
of technical factors such as KV, mA and exposure time, are
determined according to patient size and anatomical region of
interest.
Revolution 4DC, with its constant potential, high frequency X-ray
generator, significantly reduces radiation dosage compared to
traditional X-ray units. Not only is the most harmful, low energy
radiation almost completely eliminated thanks to a high-efficiency
generator, but the embedded 12” collimator minimizes the exposed
bodily surface and increases the X-ray parallelism. This leads to
better image quality and higher regard for patient’s health.
Generator
Operating frequency
Focal spot
Anode current
Voltage (kV setting)
Exposure time
Irradiated field
Total filtration
Constant potential, microprocessor controlled
145 - 230 KHz (175 KHz typical)
0.4 mm, (IEC 336)
4, 8 mA
60, 65, 70 kV
0.010 - 1.000 sec, R10 and R20 scale
Ø 60 mm round
2.5 mm Al
Line voltage
Duty cycle
50/60 Hz, 115V ± 10% or 230V ± 15%
Self regulating, continuous operation up to
1s/60s
Stability
Automatic touch-sensitive lock-on/lock-off
(HyperSphere)
Arm extension
Max arm extension
Certification
Available in 3 lengths: 40 cm - 60 cm - 90 cm
230 cm, from wall
CE 0051, cCSAus, FDA approved
NEW iM3 MyRay
Dental X-Ray
Health and Safety
Cat. No
X1400
The New iM3 MyRay Dental X-Ray Generator joins our range,
with all the same precision and quality of the iM3 Revolution but
with a traditional human double hinge system in place of the
Revolution's full-swivel ball-joint.
Trolley and wall mount options available.
PORT-X IV Portable Dental X-Ray
Cat. No
X4000
The NEW PORT-X lV provides total portability combined with the
latest digital technology.
• Light and small, enabling total portability and use in any location
PORT-X IV Technical Specifications & Dimensions
TM
X-ray Generator
X-ray Control
Weight
• High performance Tube and HFG, providing sharp and clear images
• Designed for use with both digital sensors and CR image plates
Tube Voltage
70kV
• Supplied with remote operating switch and scatter shield
Tube Current
2mA
• Fixed kV (70) and mA (2) means the only variable is the exposure time
Focal Spot
0.4mm
• X-ray tube manufactured by Toshiba
Exposure Time Set
56 Steps (0.05 – 1.6 sec)
• Complies with National Safety Standards and guidelines
Main Body
1.5 kg
• Includes Back Scatter Shield
www.im3vet.co.uk
• Small dose of radiation, ensuring patient and operator safety