PENTA ESP Electric Voltage Detectors
PENTA ESP Electric Voltage Detectors
These voltage detectors are designed for “proving dead”, making sure that nominal voltage is actually absent on a circuit in an HV
distribution system between 1 kV and 69 kV (no-voltage verification): Comes in a storage bag or metal case.
• The device detects any nominal voltage in a system or station.
• It makes it possible to avoid detecting induced voltages in order to allow earthing operations.
• The visual indication is visible in all usual working environments, in sunlight or fog, with a wide angle of visibility and from the side
thanks to an optic ring.
• The 100 dB sound signal is designed to remains audible even in traffic or strong wind, thanks to its acoustic “horn”.
Direct access to the battery and sealed electronics compartment. When the battery is replaced, this design prevents the following.
• Accidental interchange of housing or circuitry;
• Damage to electronic circuits;
• Humidity ingress into the device when the battery is replaced outdoors.
Range customizable from 1 to 69kV:
PTA-MVD1-GNG-C0425XHUC-PTA
PTA-MVD1-GNG-C2560XHUC-PTA
PTA-MVDDR1-GNG-C0469XHUC-PTA
PTA-MVDDR1-GNG-C0434XHUC-PTA
PTA-MVDDR1-GNG-C0435XHUC-PTA
Medium Voltage Detector 1 Range 04 to 25 kV
Medium Voltage Detector 1 Range 25 to 60kV
Medium Voltage Detector Dual Range 4 to 23kV & 34 to 69kV
Medium Voltage Detector Dual Range 4 to 13kV & 13 to 34kV
Medium Voltage Detector Dual Range 4kV & 13 to 35kV
These voltage detectors are designed for “proving dead”, making sure that nominal voltage is actually absent on a circuit in an HV
transmission system between 50 kV and 765 kV (no-voltage verification): The device will detect any nominal voltage on over head lines
and stations. It will avoid detecting most induced voltages in order to allow grounding operations.
Optimised indication that can be understood clearly in all working conditions:
• The visual indication is visible in all usual working environments, in sunlight or fog, with a wide angle of visibility and from the side
thanks to an optic ring.
• The 100 dB sound signal is designed to remains audible even in traffic or strong wind, thanks to its acoustic “horn”.
Direct access to the battery and sealed electronics compartment. When the battery is replaced, this design prevents the following:
• Accidental interchange of housing or circuitry;
• Damage to electronic circuits;
• Humidity ingress into the device when the battery is replaced outdoors.
PTA-HVD1-GNG-C060220XHUC-PTA
PTA-HVD1-GNG-C220500XHUC-PTA
PTA-HVD1-GNG-C069230XHUC-PTA
PTA-ADVECU
PTA-ADVECUCR
PTA-ADVECU
HVD1 High Voltage Detector 60 to 220kV
HVD1 High Voltage Detector 220 to 500 kV
HVD1 High Voltage Detector 69 to 230 kV
Replaceable Adaptor For Different Sticks End Fitting
Replaceable Adaptor For Different Sticks End Fitting
PTA-ADVECUCR
PTA-MVD1-GNG-C0412XHUC-PTA
PTA-HVD1-GNG-C060220XHUC-PTA
Range customizable from 50 to 500 kV
HD Electric TAG 200 Electronic Voltage Detectors
Range customizable from 1 to 69kV
Is an electronic voltage detector designed for detecting both distribution and transmission voltages. These direct contact type
detectors emit both audible and visual indications when placed in contact with an energized conductor. TAG's are designed for
overhead applications, but can be adapted for underground use with optional underground bushing probes. Polycarbonate housing
for heavy field use. Water resistant. All-Check self testing system. No on/off or range selector switches. Built-in universal spline for
hotstick attachment. 9V alkaline battery operated. Carrying case included.
HDE-TAG-200
TAG 200
URD Probe
CURRENT & VOLTAGE DETECTORS
CURRENT & VOLTAGE DETECTORS