VISIT TRANSMITTERS
VISIT ACCESSORIES
Visit smoke alarm – optothermal
Visit accessory
Changing the radio key
Magnetic mounting kit
Systems with only BE1481 Smoke alarm
For easy installation of smoke alarms
Step 1: Change the radio key on the BE1481 Smoke alarm
The magnetic mount kit offers a quick and easy alternative to traditional screws and plugs. It consists of a selfadhesive plate that you fix to the ceiling and a self-adhesive
magnetic plate that you attach to your smoke alarm.
1 Remove one of the batteries to turn off the smoke alarm and wait at least 30 s. Press and hold the test button as you
insert the battery again and continue holding it until the status LED goes from slow to rapid flashes. Release the button
to enter the programming mode.
2 The smoke alarm is reset to the default radio key 0 and the status LED lights up to confirm.
3 Within 4 s, press and hold the test button until the LED goes out to select the next radio key. Radio key 1 is now selected
and the status LED lights up to confirm. Follow this procedure to advance to the next radio key. There are 9 radio keys
available. If you continue beyond radio key 9, the unit will reset to radio key 0.
4 After 4 s, the smoke alarm automatically exits the programming mode and the LED goes out to confirm.
Note: Follow the steps above to change the radio key on all BE1481 smoke alarms in your Visit system.
1
2
Flashes
Lights up
Don’t release the button until
the LED flashes rapidly.
3
Radio key 0 is selected. The
LED lights up to confirm.
BE9175
Installation procedure
Technical specifications
1 Remove the protective film from the non-magnetic plate.
Diameter
70 mm
2 Mount the plate on the ceiling and hold for 10 s.
Weight
25 g
3 Remove the protective film from the magnetic plate
and attach it to the smoke alarm. Hold for 10 s.
Color
White
4 Place the smoke alarm on the ceiling plate.
Environment For indoor use only
1
Goes out
Note: The mounting kit is not suitable for vinyl
wallpapers, anti-adhesive coatings, siliconecoated or Teflon-coated surfaces. The diameter
of the smoke alarm cannot be less than 70 mm.
2
Press and hold until the LED goes
out to select the next radio key.
Steg 2: Change the radio key on the Visit receiver
1 Press and hold the test button on the receiver until the green and yellow Visit LEDs blink alternately. Release the button.
2 Press the test button on any transmitter within 25 s to transmit the new radio key.
3 All Visit LEDs on the receiver blink 5 times to show that the radio key has been changed.
1
2
10s
3
3
4
5
10s