Visit Installers guide EN - Flipbook - Sida 42
VISIT TRANSMITTERS
Visit CO alarm – electrochemical
BE1555
Installing the CO alarm
Buttons and controls
Alarm/radio LEDs
CO Sensor
Radio button
1 Remove the mounting bracket from the CO alarm by turning it counter-clockwise.
2 Taking care to avoid any electrical wiring, fix the mounting bracket to the ceiling or wall using the supplied
screws and plugs, see Location and positioning below.
3 Fit the alarm to the bracket by turning it clockwise until is snaps into place. The red, yellow and green LEDs
blink in sequence to show that the unit is on.
2
1
RADIO
3
ALARM
FAULT
POWER
CARBON
MONOXIDE
ALARM
TEST
&
HUSH
Alarm horn
Test/Hush button
Sealed battery
Technical specifications
In the box
Size and weight
CO alarm response
BE1555 Visit CO alarm
Height: 105 mm, 4.1"
Screws and plugs
Width: 120 mm, 4.7"
BE1555 is calibrated to respond to the
following levels of carbon monoxide:
User manual
Weight: 195 g, 6.9 oz. incl. battery
Activation
Environment
Via the Test/Hush button
For indoor use only
Operating temperature:
-10° to 40° C, 14° to 104° F
Humidity range: 15% to 95% R.H.
non-condensing
By carbon monoxide
Power and battery
Battery: Built-in powered for
life non-replaceable
lithium battery
Battery life: 10 years. Matches
the product lifetime.
41
Depth: 40 mm, 1.6"
Frequency and coverage
CO level/fault Alarm sound
> 43 ppm
On within 60 – 90 min.
> 80 ppm
Location and positioning
Testing the connection
Install the CO alarms in every bedroom, in every room
containing a fuel burning appliance and in remote rooms
where occupants spend a considerable amount of time.
Fit the alarms in the center of the ceiling inside every bedroom, at least 30 cm (11.8") from any wall or light fitting.
1 Wait 15 s. Press the test/hush button and release it when the
alarm sounds. The CO alarm transmits a radio signal to
the receiver.
Avoid kitchens, fireplaces or garages, as cooking fumes
and car exhaust may cause false alarms. The CO alarm
should not be installed in damp spaces, close to fans,
etc. or in agricultural buildings.
On within 2 minutes
Low battery
1 beep every minute
Faulty unit
2 beeps every minute
End of life
3 beeps every minute
Note: The alarm will stop sounding after the button is released
and the Visit receiver will time out in less than a minute.
1
On within 10 – 40 min.
>150 ppm
2 The orange and red LEDs on the Visit receiver blink alternately
to show that the signal was received. In addition, it starts to
sound, flash or vibrate depending on the receiver.
30 cm
CO alarm
2
CO alarm
15 cm
Dead air,
don’t locate
here
1–3 m
1–3 m
Radio frequency : 868.3 MHz
Coverage: Up to 200 m (218 yd.), clear
line of sight. It depends on the building’s
characteristics and radio conditions.
42