Visit Installers guide EN - Flipbook - Sida 9
VISIT TRANSMITTERS
Visit door transmitter
BE1411
Installation – intercom and electronic doorbell
Installation – hardwiring your doorbell
1 Remove the protective film from the external microphone (sold separately) and attach it to the intercom’s speaker.
Connect it to the door transmitter.
1 Pull the battery tab to start the transmitter.
Within 2 min, press the lower button 10 times to turn off the internal microphone. The LEDs will blink 3 times to confirm.
2 Pull the battery tab to start the transmitter.
Clean the wall with the wet wipe and remove the protective film from the Velcro.
2 Remove the front cover to access the screw terminal. There are 3 connection points:
Use 1 and 2 to connect an active switch, like a relay with current (2–30VDC, polarity independent
or 2–24VAC, 5 - 150Hz).
Use 2 and 3 to connect a passive switch, like a push button.
3 Mount the door transmitter to the left of the doorbell’s sound source, as close as possible.
Note: The intercom and doorbell must be at least 25 cm 10" apart to avoid sound interference.
1
2
1
2
3
3 Put the front cover back, remove the protective film from the Velcro and mount the door transmitter on the wall.
1
3
2
3
Max 3 cm, 1.2"
Electronic
doorbell
10
Ext. trig
Ext. trig
Ext. mic.
(sold separately)
Installation – intercom and mechanical doorbell
Using electromagnetic detection
If you have an intercom and a mechanical doorbell, you may need two door transmitters, i.e. one for each sound source.
The door transmitter can be set to detect electromagnetic fields emitted by electromechanical doorbells.
Here is how it’s done:
1 Pull the battery tab to start each door transmitter.
Clean the wall surfaces with the wet wipe and remove the protective films from the Velcro.
Activating electromagnetic detection: Move the 4th signal-switch to the up (on position).
2 Mount one of the door transmitters to the left of the doorbell and the other to the left of the intercom’s speaker, as close
to the sound sources as possible.
1
On
Deactivating electromagnetic detection: Move the 4th signal-switch to the down (off position).
2
Max 3 cm, 1.2"
Max 3 cm, 1.2"
Mechanical
doorbell
7
8