Visit Installers guide EN - Flipbook - Sida 39
VISIT TRANSMITTERS
Visit smoke alarm – ionization
BE1551
Setting up the smoke alarm
Overview
Signal horn
Test button
1 Remove the front cover by rotating it fully backwards and connect the battery to the battery snaps to start the unit.
The alarm will chirp during startup.
Radio LED
2 Mark the location of the screw holes and fix the smoke alarm to the ceiling using the supplied screws and plugs. Mount
it at least 30 cm, (12") from walls and other obstructions, see Location and positioning below.
3 Put the cover back on the smoke alarm by pressing gently until it snaps into place.
1
Front cover
2screw holes
Battery
Radio button
Status LED
Sensor
Technical specifications
37
In the box
Size and weight
Frequency and coverage
BE1551 Visit smoke alarm
Height: 118 mm, 4.6"
19 V alkaline battery
Width: 140 mm, 5.5"
Radio frequency
868.3 MHz
2screws and plugs
Depth: 42 mm, 1.6"
User manual
Weight: 200 g, 7 oz. incl. battery
Coverage: Up to 200 m (218 yd.), clear
line of sight. It depends on the building’s
characteristics and radio conditions.
Power and battery
Sensor type
Environment
Battery type
9 V alkaline battery
Ionization smoke detection
For indoor use only
Audible alarm
Operating temperature
4° to 40° C, 39° to 104° F
Power consumption
Idle position < 15 μA
Min 85 dB(A) @ 3m (10'), 2.6 kHz
Battery life
Minimum 3 years
Via the test button
Via the built-in smoke detector
Activation
2
3
Location and positioning
Testing the connection
Fit the smoke alarms in the center of the ceiling outside
the bedrooms, at least 30 cm from any wall. If the
bedrooms are in different areas of the house, separate
smoke alarms are recommended. In multi-storey
properties, install at least one smoke alarm on each floor.
1 Press and hold the smoke alarm test button until the alarm
sounds. The smoke alarm transmits a radio signal to the
receiver.
Avoid kitchens, fireplaces or garages, as cooking
fumes and car exhaust may cause false alarms. The
smoke alarm should not be installed in damp spaces,
close to fans, etc. or in agricultural buildings.
2 The red Visit LED on the receiver lights up to show that the
signal was received. In addition, it starts to sound, flash or
vibrate depending on the receiver.
Note: The smoke alarm will stop sounding shortly after the
button is released and the receiver will time out within 40s.
1
2
Relative humidity
15% to 95% RH, non-condensing
Smoke sensitivity
Meets the BS EN 14604:2005 standard
= Minimum
= Additional
38