Getting started
Buttons and controls
Visit LEDs
Front label
Belt clip
Battery cover
Battery eject
Battery compartment
1 Open the battery cover, fit the battery and close the cover again.
Attach the pager to your belt using the belt clip. For extra security, use the supplied safety cord.
2 To test the radio link you need a Visit transmitter. Press the test button/s on the transmitter.
3 The pager starts to vibrate and lights up a Visit LED. If a bed shaker is connected during charging, it will vibrate.
If nothing happens, see Troubleshooting.
1
2
3
1.5V AAA
Function button
Battery LED
Optional safety cord with clip
When a transmitter is activated, the pager lights up an LED and starts to vibrate with a certain pace. This is called signal
pattern. The transmitters determine the pattern, and the default is as follows:
Technical specifications
In the box
Dimensions and weight
Environment
Activated transmitter
BE1470 Visit pager receiver
Height: 86 mm, 3.4"
For indoor use only
Operating temperature
0° to 35° C, 32° to 95° F
Safety cord with clip
Width: 57 mm, 2.2"
Depth: 29 mm, 1.1"
Weight: 70 g, 2.5 oz. incl. battery
Relative humidity
15% to 90%, non-condensing
Power and battery
Visit LEDs
Frequency and coverage
Mains power
7.5 V DC 1500 mA via the charger
The Visit LEDs normally indicate
the following:
Frequency: 315 MHz, 433.92 MHz or
868.3 MHz, depending on region
Orange LED, pacifier symbol
The baby monitor is activated
Coverage by region:
315 MHz: Up to 50 m (164 ft)
433 MHz: 30 – 80 m (98 - 260 ft)
868 MHz: 50 – 250 m (55 - 273 yd)
Coverage depends on the radio
frequency, building’s characteristics
and the combination of transmitters
and receivers.
Extra front label
Battery power
1.5 V AAA alkaline or
1.2 V AAA NiMH rechargeable battery
Operation time
Alkaline battery: 2 – 3 weeks
NiMH battery: ~1 week
Power consumption
Active: 220 mA
Idle position: ≤1 mA
53
Default signal pattern
Green LED, door symbol
The door transmitter is activated
Yellow LED, telephone symbol
The phone transmitter is activated
Red LED, fire symbol
The smoke alarm is activated
Orange and red LEDs blink alternately
The CO alarm is activated
Accessories
BE1260 Pager charger
BE1270 Bed shaker
Door transmitter
Push button transmitter
Telephone transmitter
Baby monitor
Smoke alarm
CO alarm
Pager LED
Pager / bed shaker vibration
Green
Green
Yellow
Orange
Red
Orange and red
Slow
Slow
Medium
Fast
Long
Long
Changing the signal pattern
The signal pattern can only be changed on the transmitters. See Changing the signal pattern for the relevant transmitter.
Changing the front label
If you want to use Visit for other purposes, the pager front label can be replaced with a customized one. Here is how it’s done:
Open the battery cover, replace the original label with the supplied extra label and close the cover again.
Replacing the battery
When the battery LED starts to blink in yellow, the battery is nearly depleted. Here is how you replace it:
Open the battery cover and press the battery eject button to remove the old battery. Insert a 1.5 V AAA alkaline battery
or a 1.2 V AAA NiMH rechargeable battery if you are using the BE1260 charger accessory.