Joiners-Manual-V05 Pages LR - Flipbook - Page 241
Part Q | Double Door - Open Out
Part Q
What ComPonents do I need to use?
master Lock, slave Lock, shoobolt and Keep Kit
mL30s-KIt-45-a
mL30s-KIt-45-B
mL30s-KIt-45-C
mL30s-KIt-45-d
mL30s-KIt-45-e
mL30s-KIt-45-F
See PAGe
Solo Double Door Kit for Leaf Height 1853 - 1996mm (Left or Right Hand)
pg 28
Solo Double Door Kit for Leaf Height 1997 - 2139mm (Left or Right Hand)
pg 28
Solo Double Door Kit for Leaf Height 2140 - 2281mm (Left or Right Hand)
pg 28
Solo Double Door Kit for Leaf Height 2282 - 2425mm (Left or Right Hand)
pg 28
Solo Double Door Kit for Leaf Height 2426 - 2567mm (Left or Right Hand)
pg 28
Solo Double Door Kit for Leaf Height 2496 - 2639mm (Left or Right Hand)
pg 28
euro Cylinder
KPd
KPt
3 Star Security TS007 Euro Profile Double Cylinder (Key/Key)
Any size
pg 56
3 Star Security TS007 Euro Profile Thumbturn Cylinder (Turn/Key)
Any size
pg 57
Any door handle can be used - All security is covered within the KPD/KPT euro cylinder tested.
Butt hinge
hQ4-316
hQ4R-316
hQ4-316-seC
102 x 76 x 3mm Phosphor Bronze - Square End Hinge - 316 Grade Stainless Steel
pg 158
102 x 76 x 3mm Phosphor Bronze - Round End Hinge - 316 Grade Stainless Steel
pg 158
102 x 76 x 3mm Phosphor Bronze - Square End Security Dogbolt Hinge - 316 Grade Stainless Steel
pg 158
3 hinges required for doors up to 2210mm or 120kg max weight.
seals
sPV124-15
sPV124-18
CF1612
15mm Rebate
Frame Weatherseal
pg 212
18mm Rebate
Frame Weatherseal
1.6 x 12mm
CoFirm Double Sided Glazing Tape
pg 212
4 x 40mm
Red Horse Screws for lock and keep fixings
pg 224 - 225
5 x 40mm
Red Horse Screws for fixing butt hinges
pg 224 - 225
5 x 90mm
Red Horse Screws for fixing frame assembly
pg 224 - 225
Larger tapes can be used
pg 222
Fixings
FX-RhF440
FX-RhF540
FX-RhF590
If using acidic timber we recommend using the stainless steel Red Horse Screws.
Other Information
am3eX, tsY & tsW Aluminium Thresholds and Hollodeen Thresholds can be used.
What was used in the test (worst case scenario):
Glass - 4/16/4 - Toughened Double Glazed with at least one pane of laminated glass meeting the requirements of BS EN 356:2000, Class P1A, and be glazed in
accordance with BS 6262.
note on glazing - The glass used in the test must be at least 4mm toughened glass. However, the glass used in the final doorset must contain at least one pane
of BS EN 350, P1A security glass which is usually 6.8mm laminated. All glass in a doorset should be safety glass. This is to comply with Part Q, glass should also
comply with Building Regulations.
timber - Accoya (Density - Average 512 kg/m3, Range 432 - 592 kg/m3 as per Accoya datasheet).
Visit www.coastal-group.com/partq for more information or contact us on sales@coastal-group.com
or 01726 871 025 to discuss your project.
241
Knowledgeable, technical and experienced
our team is always on hand to support you
01726 871 025 | sales@coastal-group.com | www.coastal-group.com