Joiners-Manual-V05 Pages LR - Flipbook - Page 243
Part Q | Folding Door System - Open Out
Part Q
What ComPonents do I need to use?
hardware - Hardware depends on scheme required, please check.
CoFold 100
sF190L / 450L / 600L
mL60R
mL60s
mK7-FLu
mK9
KPd
KPt
See PAGe
See the folding door system...
pg 176
SF Locking Flush Bolts (190/450/600mm)
pg 178
20mm Radius End
45 or 55mm Backset
Twin Tapered Deadbolt Lock
pg 15
20mm Square End
45mm Backset
Twin Tapered Deadbolt Lock
pg 15
Single Adjustable Keep
pg 44
Centre Adjustable Keep (Left or Right Hand)
pg 44
3 Star Security TS007 Euro Profile Double Cylinder (Key/Key)
Any size
pg 56
3 Star Security TS007 Euro Profile Thumbturn Cylinder (Turn/Key)
Any size
pg 57
Any door handle can be used - All security is covered within the KPD/KPT euro cylinder tested.
seals
aQ21
aQ63
CF1618
Ps13-6
Aquamac 21 Frame Perimeter Seal
pg 215
Aquamac 63 Door Perimeter Seal
pg 215
CoFirm Double Sided Glazing Tape - 1.6 x 18mm
Larger tape can be used if required
Track Brush Seal
pg 222
pg 178
Fixings
hB740-sV
FX-RhF590
FX-RhF550
FX-RhF440
FX-RhF430
Security Dogbolt Set
pg 164
5 x 90mm
Red Horse Screws for fixing assembly
pg 224 - 225
5 x 50mm
Red Horse Screws for fixing flush bolts
pg 224 - 225
4 x 40mm
Red Horse Screws for fixing hinges
pg 224 - 225
4 x 30mm
Red Horse Screws for fixing door espag & keeps
pg 224 - 225
If using acidic timber we recommend using the stainless steel Red Horse Screws.
tracks
250
t94P
t94sC
Top Track
pg 178
Bottom Polypropylene Channel
pg 178
Aluminium Support Channel
pg 178
Other Information
sF94t Aluminium Thresholds and Hollodeen Thresholds can be used.
What was used in the test (worst case scenario):
Glass - 4/16/4 - Toughened Double Glazed with at least one pane of laminated glass meeting the requirements of BS EN 356:2000, Class P1A, and be glazed in
accordance with BS 6262.
note on glazing - The glass used in the test must be at least 4mm toughened glass. However, the glass used in the final doorset must contain at least one pane
of BS EN 350, P1A security glass which is usually 6.8mm laminated. All glass in a doorset should be safety glass. This is to comply with Part Q, glass should also
comply with Building Regulations.
timber - Accoya (Density - Average 512 kg/m3, Range 432 - 592 kg/m3 as per Accoya datasheet).
Visit www.coastal-group.com/partq for more information or contact us on sales@coastal-group.com
or 01726 871 025 to discuss your project.
243
Combining market leading
products with unrivalled technical knowledge
01726 871 025 | sales@coastal-group.com | www.coastal-group.com