Joiners-Manual-V05 Pages LR - Flipbook - Page 247
Part Q | High Performance Flush Timber Window - Top Hung
Part Q
What ComPonents do I need to use?
hardware
eBt0200-22
eBt0400-22
eBt0600-22
eBt0800-22
eBt1000-22
eBt1200-22
eBsK
dt8
dt12
dt16
dt20
dth24
LCs20
LCs50
LCs60
See PAGe
200mm
Bi-Directional Window Espag - Twin Cam
pg 107
400mm
Bi-Directional Window Espag - Twin Cam
pg 107
600mm
Bi-Directional Window Espag - Twin Cam
pg 107
800mm
Bi-Directional Window Espag - Twin Cam
pg 107
1000mm
Bi-Directional Window Espag - Twin Cam
pg 107
1200mm
Bi-Directional Window Espag - Twin Cam
pg 107
Night Vent Keep
pg 108
203mm
Top Hung Defender Friction Hinge
pg 114
305mm
Top Hung Defender Friction Hinge
pg 114
406mm
Top Hung Defender Friction Hinge
pg 114
508mm
Top Hung Defender Friction Hinge
pg 114
610mm
Top Hung Defender Friction Hinge
pg 114
Locking Claw
pg 143
Stepped Stabilising Plate
pg 108
Flat Stabilising Plate
pg 108
seals
sPV124-18
CF1610
CF1612
18mm Rebate
Frame / Sash Weatherseal
1.6 x 10mm
CoFirm Double Sided Glazing Tape
Larger tape can be used if required
pg 222
pg 212
1.6mm x 12mm
CoFirm Double Sided Glazing Tape
Larger tape can be used if required
pg 222
4 x 30mm
Red Horse Screws for fixing hardware to sash
pg 224 - 225
4 x 40mm
Red Horse Screws for fixing hardware to frame
pg 224 - 225
5 x 90mm
Red Horse Screws for Frame Fixing
pg 224 - 225
Fixings
FX-RhF430
FX-RhF440
FX-RhF590
If using acidic timber we recommend using the stainless steel Red Horse Screws.
Other Information
What was used in the test (worst case scenario):
Glass - 4/16/4 - Toughened Double Glazed with at least one pane of laminated glass meeting the requirements of BS EN 356:2000, Class P1A, and be glazed in
accordance with BS 6262.
note on glazing - The glass used in the test must be at least 4mm toughened glass. However, the glass used in the final window, where non-key locking
hardware is used, must contain at least one pane of BS EN 350, P1A security glass which is usually 6.8mm laminated. Windows with key locking hardware can
be fitted with annealed glass unless toughened or laminated glass is required for safety reasons. This is to comply with Part Q, glass should also comply with
Building Regulations.
timber - Accoya (Density - Average 512 kg/m3, Range 432 - 592 kg/m3 as per Accoya datasheet).
Visit www.coastal-group.com/partq for more information or contact us on
sales@coastal-group.com or 01726 871 025 to discuss your project.
FYI...
This window
achieved class 3.5
in Air Permability
Test (4 is highest
rating)
247
Coastal Group – the UK’s leading
provider of door and window hardware
01726 871 025 | sales@coastal-group.com | www.coastal-group.com