Joiners-Manual-V05 Pages LR - Flipbook - Page 251
Part Q | Tritus Flush Casement Timber Window - Top Hung
Part Q
What ComPonents do I need to use?
hardware
Fe0440
Fe0520
Fe0600
Fe0720
Fe0820
Fe0920
Fe1020
Fe1120
FC4050
LCs60
FCK100
FCK300
FCK350
FCK800
FCK900
FCK850
FCK950
FCK6050
Fh70
See PAGe
440mm
Ear Type Espag Bolt
pg 122
520mm
Ear Type Espag Bolt
pg 122
600mm
Ear Type Espag Bolt
pg 122
720mm
Ear Type Espag Bolt
pg 122
820mm
Ear Type Espag Bolt
pg 122
920mm
Ear Type Espag Bolt
pg 122
1020mm
Ear Type Espag Bolt
pg 122
1120mm
Ear Type Espag Bolt
pg 122
ShootBolt Extension Set
pg 124
Flat Stabilising Plate
pg 108
Flat Night Vent Keep
pg 123
Night Vent Keep with Lip Return
pg 123
Night Vent Keep without Lip Return
pg 123
Corner Shootbolt Keep
pg 124
Corner Shootbolt Keep
pg 124
Corner Shootbolt Night Vent Keep
pg 125
Corner Shootbolt Night Vent Keep
pg 125
Friction Restrictor
pg 127
Lift-off Butt Hinge*
pg 120
*FH70 - minimum of 3 hinges required per sash. As these hinges are handed you will need two of one hand and one of the other hand
seals & tapes
sPV124-18
CF1618
18mm Rebate
Frame / Sash Weatherseal
1.6mm x 18mm
CoFirm Double Sided Glazing Tape
pg 212
4 x 30mm
Red Horse Screws for fixing hardware to sash
pg 224 - 225
4 x 40mm
Red Horse Screws for fixing hardware to frame
pg 224 - 225
5 x 90mm
Red Horse Screws for Frame Fixing
pg 224 - 225
Larger tape can be used if required
pg 222
Fixings
FX-RhF430
FX-RhF440
FX-RhF590
If using acidic timber we recommend using the stainless steel Red Horse Screws.
Other Information
What was used in the test (worst case scenario):
Glass - 4/16/4 - Toughened Double Glazed with at least one pane of laminated glass meeting the requirements of BS EN 356:2000, Class P1A, and be glazed
in accordance with BS 6262.
note on glazing - The glass used in the test must be at least 4mm toughened glass. However, the glass used in the final window, where non-key locking
hardware is used, must contain at least one pane of BS EN 350, P1A security glass which is usually 6.8mm laminated. Windows with key locking hardware can be
fitted with annealed glass unless toughened or laminated glass is required for safety reasons. This is to comply with Part Q, glass should also comply with
Building Regulations.
timber - Accoya (Density - Average 512 kg/m3, Range 432 - 592 kg/m3 as per Accoya datasheet).
Visit www.coastal-group.com/partq for more information or contact us on sales@coastal-group.com or
01726 871 025 to discuss your project.
251
We don’t just supply products
– we build valuable relationships with our customers
01726 871 025 | sales@coastal-group.com | www.coastal-group.com