Fluke Networks Range
FiberInspectorTM Pro
Fluke Networks Range
DSX-600 CableAnalyzerTM
End-face contamination is a leading cause of fibre failures. Dirt and contaminant cause insertion loss and back-reflection that
inhibits optical transmission and causes havoc with transceivers. Fibre loss and OTDR testing can expose this problem,
but in many cases, dirty connections make fibre testing time consuming and inaccurate. Since dirt can be an issue before,
during, or after fibre optic certification testing, and migrate from one end-face to another upon mating, both sides of
any connection must always be cleaned and inspected. The FI-7000 FiberInspector Pro enables you to quickly inspect
and certify fibre end-faces inside ports or patch cords. Its 2-second automated PASS/FAIL certification eliminates human
subjectivity and enables anyone to become a fibre inspection expert.
The DSX-600 CableAnalyzer™ is the essential certification tool for copper, twisted pair structured cabling from Cat 3/Class
C through Cat 6A/Class EA features speed, and reliability that makes you more efficient and productive – you can see the
results on the bottom line. No other tester will deliver as consistently as the DSX-600. Its gesture-based user interface
allows your techs to spend less time interpreting screens and more time testing. 500 MHz frequency range certifies Cat
6A/Class EA cabling for 10 Gigabit Ethernet in just 10 seconds. Advanced diagnostics pinpoint the location of a failure and
suggest corrective action.
Features & Benefits
Ordering Information
• Automated Pass/Fail acceptance testing of fibre end-faces
• Graphical indication of problem areas due to contamination,
pits, chips, and scratches.
• Large touch-screen for pinch and zoom.
• Certify to industry standards – IEC 61300-3-35.
• No more confusion about whether the fibre is good or bad.
• Eliminate human subjectivity from end-face measurements.
• Save end-face views during certification process.
• Reduce fibre inspection time with 2-second grading.
• ProjX™ system manages job requirements and progress
from set-up to systems acceptance, making sure all tests are
completed correctly.
• Taptive™ user interface simplifies set-up, and eliminates error
• Analyze test results and create professional test reports using
LinkWare™ management software.
Product Description
Part Number
Fl-500 INTL
00A-500-009-05
Fl-7000 INTL
00A-500-009-50
Specifications
Specifications
• Entry-level copper certifier for Category 6A and Class EA
copper installations.
• Increased productivity and enhanced ROI to small cable
installation jobs.
• Cat 6A Autotest in 10 seconds.
• Compatible with LinkWare Live.
Display
Battery life
Operating altitude
4,000 m (13123 ft), 3200 m (10,500
ft) with ac adapter
DSX-600 INTL
00A-500-000-70
Mainframe with module and
battery: 3 lbs, 5 oz (1.28 kg)
DSX-600-PRO INTL
00A-500-000-75
GLD-DSX-600
00A-400-001-47
GLD-DSX-600-PRO
00A-400-001-48
Weight
Dimensions
Safety
5.7 in LCD touch-screen display
CSA 22.2 No. 61010, IEC 61010-1 3rd
Edition
Weight
3 lbs (1.36 kg)
2.625 in x 5.25 in x 11.0 in
(6.67 cm x 13.33 cm x 27.94 cm)
Dimensions
EMC
Ordering Information
Eleven hour with Inspection probe
attached
Mainframe with module and
battery: 2.625 in x 5.25 in x 11.0 in
(6.67 cm x 13.33 cm x 27.94 cm)
Product Description
Part Number
TIA
ISO/IEC
EN 61326-1: Portable
Category 3, 5, 5e, 6, 6A per TIA 568-C.2
or TIA-1005
Class C and D, E, EA certification per ISO/
IEC 11801:2002 and amendments
Operating Temperature
Storage Temperature
Feature
32° F to 113° F (0° C to 45° C)
-22° F to +140° F (-30° C to +60° C)
DSX-600
DTX-1500
Essential Cat 6A
& Class EA
copper tester
Cat 6A & Class EA
copper tester
Cat 3 - 6A/Class EA
Class FA
Cat 8/Class I/II
Description
Non-operating temperature
-30ºC to 60ºC
EMC
EN 61326-1
Charge time
Four hours to charge from 10% 90% capacity
Operating Temperature
-18ºC to 45ºC
Probe 2M pixels
Blue LED
Probe Light source
Blue LED
Max. Frequency
500 MHz
500 MHz
Probe Power source
Versiv mainframe
Auto-test Time
22s: Class EA/Cat 6A
9s: Class E/Cat 6A
Probe Field of View (FOV)
Horizontal: 425 μm, Vertical: 320
μm
10s: Class EA/Cat 6A
9s: Class E/Cat 6A
Shield Integrity Test
Probe Minimum detectable
particle size
0.5 μm
Permanent Link
Adapter
Optional
Optional
Probe Dimensions
Approximately 6.75 in x 1.5 in
(1175 mm x 35 mm) without adapter
tip
Advanced Fault Info
Troubleshooting
Limited
(HDTDR & HDTDX)
Limited
Probe Weight
200G
PoE Resistance
Unbalance
Integrated Alien
Crosstalk Capability
Coax Adapters
Optional
Optional
M12 Adapters
Optional
Optional
Patch Cord Adapters
Fibre - OLTS, OTDR
& Inspection
Operating Temperature range 32°F to 122°F (0 °C to +50 °C)
Storage Temperature range
-4°F to +158°F (-20°C to +70°C)
Probe Certifications
CE
Battery
Lithium ion battery pack, 7.2 volts
Storage altitude
5
Features & Benefits
12,000mB
+44 (0)1376 346 600 | sales@connectix.co.uk | www.connectixcablingsystems.com