PRE-INSTALL
EXTRACTION
INTRODUCTION
A gas only oven can be extracted with two different methods.
It can have a direct twin walled flue system or an industrial
extraction canopy.
OPTION 1 - FLUE
For a direct flue the oven will require direct connection
to a 150mm (5.9 inch) internal diameter, twin walled flue
system that is appropriate for solid fuel burning. Refer to
the manufacturer’s guidelines regarding installation and
clearances.
Extraction option 1 - Flue
OPTION 2 - CANOPY
When operating a Gozney Oven exclusively on gas, it may be
possible to utilise an existing or new kitchen extract system
via the use of an extraction canopy.
ALWAYS CHECK WITH YOUR EXTRACTION PROVIDER PRIOR
TO USING YOUR OVEN.
When using a canopy for extraction of gas emissions, always
ensure that the canopy is working to a sufficient level prior
to gas burner ignition. In addition, canopy extraction should
remain on for at least 5 minutes after the gas burner flame
has been fully extinguished.
If adding any kind of facade to the oven, always ensure that
proper access is maintained, including sufficient room for
maintenance to the extraction canopy filters.
Extraction option 2 - Canopy
12
Unit 18 & 19, The Runway,
Christchurch, Dorset.
BH23 4FL.
w www.gozney.com
e enquiries@gozney.com
t +44 (0)1425 204 999
WARNING: EMISSIONS FROM THE OVEN WILL BE HOT
AND DISTANCES FROM ANY COMBUSTIBLES (INCLUDING
COMBUSTIBLE EXTRACTION COMPONENTS) MUST BE
ADHERED TO.