Copy of print copy of brochure without bleed - Flipbook - Page 45
RETRACABLE TUNNELS
Complete with extraction,
lighting and air intake
Light System
Filtration
System
Ventilation
System
Heating
System
Control Board
Ceiling Lighting
8Units, each4× 36W, Total 1152W, grade of lighting box’ s
dustproof and waterproof reach IP54 grade.
Side Lighting
8Units, each2× 36W, Total 576W, grade of lighting box’ s
dustproof and waterproof reach IP54 grade.
Brightness
≥ 1000 LUX
Pre-filters
Grade G2 plate type fiber glass filter
Ceiling Filters
EU5 grade high efficient filter
Bottom filter & exhaust filter
Fibreglass paint-stop filter
Inlet fan (Direct drive motor)
Adopt big impeller turbo fan 7.5KW, 380V, 50HZ, CE
Outlet fan (Direct drive motor)
Adopt big impeller turbo fan 5.5KW, 380V, 50HZ, CE
Painting and baking exchange
system
Solenoid valve+ pressure adjustment control cylinder
driven damper exchange
Total fan Capacity
20, 000m³ /h
Air Flow Speed in cabin
0.23m/s in empty booth, 0.25-0.35m/s in loaded booth
Heating Exchanger
Adopt high efficient heat-resistant stainless steel as
cycling heat exchanger
Heating Exchange Capacity
160KW(180, 000Kcal/H)
Burner Model
Adopt Italy RIELLO diesel burner G20(180, 000kcal/H)
Heating time
4-6minutes (from20 to 60º C) under baking status, max
baking temperature is 80° C
Control system
Standard Y/Δ step-down start control system
Function
Painting, warm painting, baking, lighting, emergency stop
switch, failure indication, over-temperature alarm
indication