SERIES 65 CONVENTIONAL DETECTORS
APOLLO SERIES 65
SMOKE DETECTOR
Conventional smoke detectors housed in
an attractive white polycarbonate case
Packaging designed to act as
dust cover until commissioning
of system
Externally visible LED illuminates when
detector changes to
alarm state
Approved to EN54-7:2000
9-33v supply voltage
CODE
PART NO.
DETECTOR BASES
The Series 65 diode base is designed for
use with conventional systems that have
manual callpoints and detector bases on
the same circuit.
DESCRIPTION
CODE
127-1000 55000217APO
Series 65 Ionisation Smoke
Detector
127-1008 45681201APO
127-1001 55000317APO
Series 65 Optical Smoke
Detector
APOLLO SERIES 65 HEAT DETECTOR
Conventional smoke detectors
housed in an attractive white
polycarbonate case
Packaging designed to act as
dust cover until commissioning of
system
Externally visible LED illuminates when
detector changes to
alarm state
Approved to EN54-5:2000
9-33v supply voltage
CODE
PART NO.
DESCRIPTION
127-1003 55000122APO
Series 65 Rate of Rise Heat
Detector A1R
127-1004 55000127APO
Series 65 Rate of Rise Heat
Detector Class BR 75
127-1155 55000132APO
Series 65 Class CR Heat
Detector
127-1006 55000137APO
Series 65 Class CS Heat
Detector
PART NO.
DESCRIPTION
Series 65 Diode Detector
Base
FLAME DETECTOR
HOCHIKI CONVENTIONAL DETECTORS
HOCHIKI CONVENTIONAL
PHOTOELECTRIC SMOKE DETECTOR
Removable, high performance chamber
32 user- selectable tones
Remote indicator output
3 user selectable volumes
Wide voltage range 9.5v -30v
Max 93dB volume
Low profile design
Approved by LPCB and VdS
CODE
PART NO.
DESCRIPTION
CODE
PART NO.
DESCRIPTION
127-1077
SLR-E3N
Photoelectric Smoke
Detector
128-1049
CSB-E
Conventional Sounder
Base
CONVENTIONAL HEAT DETECTORS
The AFD1 UV Flame detector is
designed to protect enclosed indoor
areas where open flaming fires may
be expected. The detector has a fast
acting response to flames up to 25M
away.
CODE
PART NO.
DESCRIPTION
127-1154
55000025APO
Series 65 Class CR Heat
Detector
CONVENTIONAL
SOUNDER BASE
CONVENTIONAL
DETECTOR BASES
Electronic linear heat detection
Integral remote indicator output
Remote Indicator Output
Low profile design - only 8mm
Wide voltage range 9.5v – 30v
Electronics free
Twin LED’s for 360º viewing
Quick connection
CODE
PART
DESCRIPTION
NO.
127-1173
DCD-AE3
Rate of Rise Detector 60ºC
127-1174
DCD-CE3
Rate of Rise Detector 90ºC
127-1175
DFJ-AE3
Fixed Temp Detector 60ºC
127-1176
DFJ-CE3
Fixed Temp Detector 90ºC
CONVENTIONAL FLAME DETECTOR
CODE
PART NO.
DESCRIPTION
127-1163
YBN-R/6
Conventional Detector
Base
127-1084
YBN-R/6SK
Conventional Detector
Base c/w Diode
CONVENTIONAL SOUNDER
BEACON BASE
APOLLO SERIES 65 RELAY DETECTOR BASE
The Series 65 12V Relay Base is designed for use in both fire and
security systems. For fire systems a jumper on the PCB is fitted to
a ‘latching’ position. For security systems the jumper is moved to
another position so that the base is ‘non-latching’.
CODE
PART NO.
127-1156 45681508APO
80
DESCRIPTION
Series 65 12V Relay Detector
Base
Class 1 performance as defined in BS EN54 -10:2002
32 user-selectable tones
Detection range up to 25M
3 user selectable volumes
Single Infrared Technology
Max 93dB volume
Twin LED’s for 360º viewing
High intensity LED’s to minimise current consumption
CODE
PART NO.
DESCRIPTION
CODE
PART NO.
DESCRIPTION
127-1172
DRD-E
Flame Detector
128-1048
CSBB-E
Conventional Sounder
Beacon Base