TWO-WIRE FIRE ALARM PANELS
Most conventional fire systems are designed to work with two pairs of wires per zone, one pair for detection devices
like call points and smoke/ heat detectors; the other for alarm devices such as sounders, bells and beacons. By using
different voltage bands for quiescent and alarm states, AlarmSense components can be connected to the same pair of
wires. This greatly reduces labour costs and cable. Research has shown that using a two wire system can achieve a 2025% reduction of labour costs over a conventional 4 wire system.
C-TEC TWO-WIRE
ALARMSENSE ALARM PANELS
Complies fully with EN54: parts 2 & 4
TWO-WIRE DETECTORS
APOLLO ALARMSENSE DEVICES
ALARMSENSE SMOKE DETECTORS
Responds well to slow-burning smouldering fires.
2 LED’s for 360º Visibility
Reduces false alarms
Attractive flush or surface mountable plastic lid and enclosure
Four conventional sounder circuits for use with conventional sounders.
Class change and alert inputs
Two on-board relays for fire and fault
Wide range of engineering functions including zone test, coincidence,
non-latching zones and zone delay.
CODE
PART NO
DESCRIPTION
127-1147
55000-390APO
Alarm Sense Optical Smoke
Detector
127-1146
55000-392APO
Alarm Sense Optical Smoke
Detector c/w Sounder Base
127-1018
55000-394APO
AlarmSense Optical Smoke
Detector c/w Sounder Beacon
Base
End of line units included, one per zone
CODE
PART NO
DESCRIPTION
126-1012
CFP702-2
CFP AlarmSense 2 wire Fire Alarm Panel - 2 Zone
126-1013
CFP704-2
CFP AlarmSense 2 wire Fire Alarm Panel - 4 Zone
126-1014
CFP708-2
CFP AlarmSense 2 wire Fire Alarm Panel - 8 Zone
126-1003
CFP760
CFP Panel - 8 Zone Repeat
126-1027
CFP761
CFP Network Driver Card
(1 required for each Repeater)
126-1005
CFP762
CFP Relay output card.
Provides reset, fault, aux & remote relay outputs
126-1087
S-KEY
Spare Key for CFP Keypad
ALARMSENSE HEAT DETECTORS
Can be used for applications where smoke detectors are
unsuitable, such as dusty and smoky environments.
CS type detectors are ideal for use in environments of
rapid temperature fluctuation such as boiler rooms
2 LED’s for 360º visibility
KENTEC TWO-WIRE
ALARMSENSE ALARM PANELS
High specification
Settings easily programmed
Easily installed
Uses Apollo AlarmSense and its features
86
CODE
PART NO
DESCRIPTION
126-1119
KA11020 M2
Sigma CP - A AlarmSense Conventional 2 Zone
126-1120
KA11040 M2
Sigma CP - A AlarmSense Conventional 4 Zone
126-1121
KA11080 M2
Sigma CP - A AlarmSense Conventional 8 Zone
Reduces false alarms
CODE
PART NO
DESCRIPTION
127-1144
55000-190APO
Alarm Sense Rate of Rise Heat
Detector, Class A1R 57D
127-1021
55000-193APO
Alarm Sense Static Heat Detector
Class CS 90c
127-1022
55000-196APO
Alarm Sense Rate of Rise Heat
Detector Class A1R 57c c/w
Sounder Base
127-1023
55000-197APO
Alarm Sense Static Heat Detector
Class CS 90c c/w Sounder Base
127-1024
55000-198APO
Alarm Sense Rate of Rise Heat
Detector Class A1R 57c c/w
Sounder Beacon Base
127-1025
55000-199APO
Alarm Sense Static Heat Detector
Class CS 90c c/w Sounder Beacon
Base
87





Powered by


Full screen Click to read
Paperturn flipbook viewer
Search
Overview
Download as PDF
Print
Shopping cart
Full screen
Exit full screen