2020 catalogue FSP - Page 89



TWO-WIRE SYSTEMS ACCESSORIES
ADDRESSABLE FIRE ALARM PANELS
AASB
ALARMSENSE DETECTOR BASES ONLY
XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM PANELS
CODE
PART NO
DESCRIPTION
127-1026
45681-244APO
AlarmSense Detector Base
127-1027
45681-510APO
AlarmSense Detector Sounder Base
127-1028
45681-509APO
AlarmSense Detector Sounder Beacon Base
127-1030
45681-294APO
White Locking Cap
Full compatibility with Apollo’s XP95/Discovery and Hochiki’s
Two independently programmable conventional sounder circuits
127-1073
45681-309APO
Ceiling tile mounting box for standard detectors
ESP protocols
Two programmable inputs
127-1074
45681-310APO
Ceiling tile mounting box for Sounder or Beacon
Detector bases
The ability to interconnect up to eight XFP main panels (any variant)
A fault output relay and three programmable relay outputs with
XFP range of networkable analogue addressable fire panels offer high performance at a competitive price. Certified to
the latest versions of EN54 parts 2 & 4 by the Loss Prevention Certification Board, two versions are available - a costeffective single loop 16 zone panel in a plastic enclosure and a robust 1 or 2 loop 32 zone metal panel. Ideal for use
in office blocks, shopping complexes and big industrial sites as well as smaller stand-alone applications, both versions
offer an array of user and installer-friendly features including:-
AASSB
onto a two wire RS485 network. Alternatively, up to eight XFP
repeaters can be connected to a non-networked XFP main panel
Detects the removal of a detector head and reports a fault
Red and White caps are available for the sounder and visual versions
so they can be used without a detector.
voltage free changeover contacts
AAB
XFP SINGLE LOOP 16 ZONE FIRE PANELS - LPCB APPROVED TO EN54-2/4
70-87 dB range on sounder versions
CODE
PART NO
DESCRIPTION
Ceiling tile mounting boxes can be used with tiles up to 25mm thick
126-1100
XFP501E/X
XFP Networkable single loop 16 zone panel (XP95/Discovery)
Keypad/keyswitch entry, plastic enclosure
126-1099
XFP501E/H
XFP Networkable single loop 16 zone panel (Hochiki ESP)Keypad/
keyswitch entry, plastic enclosure
ALARMSENSE RELAY
CODE
PART NO
DESCRIPTION
127-1033
55000-835APO
AlarmSense Alarm Relay
AlarmSense Alarm Relay
Enables devices such as visual indicators, pillow/bed alarms, radio vibrating and
paging devices to be connected to the system.
Ensures DDA compliance
ALARMSENSE OPEN AREA ALARM DEVICES
CODE
PART NO
DESCRIPTION
127-1034
55000 - 018APO
Alarm Sense Open Area Sounder - Red
127-1035
55000 - 017APO
AlarmSense Open Area Sounder Beacon - Red
XFP 1 & 2 LOOP 32 ZONE FIRE PANELS - LPCB APPROVED TO EN54-2/4
CODE
PART NO
DESCRIPTION
126-1097
XFP501/X
XFP Networkable one loop 32 zone panel (XP95/Discovery)
Keypad/keyswitch entry, c/w 3A psu, metal enclosure
126-1096
XFP501/H
XFP Networkable one loop 32 zone panel (Hochiki ESP)Keypad/
keyswitch entry, c/w 3A psu, metal enclosure
126-1102
XFP502/X
XFP Networkable two loop 32 zone panel (XP95/Discovery)
Keypad/keyswitch entry, c/w 3A psu, metal enclosure
126-1101
XFP502/H
XFP Networkable two loop 32 zone panel (Hochiki ESP)Keypad/
keyswitch entry, c/w 3A psu, metal enclosure
XFP REPEATERS FIRE PANELS
CODE
PART NO
DESCRIPTION
126-1098
XFP510-16
XFP Networkable repeater panel, 16 zones (all protocols)Keypad/
keyswitch entry, c/w psu, plastic enclosure
126-1104
XFP510-32
XFP Networkable repeater panel, 32 zones (all protocols)Keypad/
keyswitch entry, c/w psu, metal enclosure
Polarity insensitive
IP65 Rated
XFP NETWORK COMMUNICATION CARDS
ALARMSENSE MANUAL CALL POINT
CODE
PART NO
DESCRIPTION
127-1145
55400 - 894APO
Alarm Sense Manual Call Point - Resettable
127-1037
55100 - 894APO
Alarm Sense Manual Call Point
Compliant with EN54:11 - can be detected as an operated call point rather
than a detector that has changed to the alarm state.
Red LED to signal alarm
CODE
PART NO
DESCRIPTION
126-1027
CFP761
XFP Network communication card for XFP 16 zone main panels
126-1081
AFP711
XFP Network communication card for XFP 32 zone main panels
(One network communication card is required per networked main panel. Note that
repeater panels are supplied with a network communication card already fitted).
XFP PROGRAMMING SOFTWARE
CODE
PART NO
DESCRIPTION
126-1103
XFP507
XFP Upload download software kit (all protocols) Windows 98,
2000, XP includes programming lead
126-1030
SAF7070000
2m Programming lead ONLY
Resettable Element
88
89





Powered by


Full screen Click to read
Paperturn flipbook viewer
Search
Overview
Download as PDF
Print
Shopping cart
Full screen