The Operating Theatre Journal - Flipbook - Page 29
data from patient reported outcomes.
Becker’s Hospital Review webinar. October
3, 2019. Accessed October 18, 2019. www.
ATTUNEevidence.com/clinical‐ evidence.
11 Ranawat CS, White PB, West S, Ranawat AS.
Clinical and radiographic results of ATTUNE
and PFC SIGMA knee designs at 2‐year
follow‐up: a prospective matched‐ pair
analysis. J Arthroplasty. 2017;32:431‐436.
12 Indelli PF, Pipino G, Johnson P, Graceffa
A, Marcucci M. Posterior‐ stabilized total
knee arthroplasty: a matched pair analysis
of a classic and its evolutional design.
Arthroplasty Today. 2016;2:193‐ 198.
13 P昀椀tzner, T., et al. (2018). “Modi昀椀cations of
femoral component design in multi‐radius
total knee arthroplasty lead to higher lateral
posterior femoro‐ tibial translation.” Knee
Surgery, Sports Traumatology, Arthroscopy
26(6): 1645‐1655.
14 Clatworthy, M., Patient‐Speci昀椀c TKA with
the VELYSTM Robotic‐ Assisted Solution.
Surg Technol Int, 2022. 40.
We will continue to invest in this technology
with our service and our hospital and
contribute to further scienti昀椀c research,”
declared Dr. Pieter-Jan Vandekerckhove.
Through VELYS™ Digital Surgery and the VELYS™
Robotic-Assisted Solution, DePuy Synthes
makes a strategic, long-term commitment to
digital health innovation that will shape the
future of orthopedic care. The VELYS™ RoboticAssisted Solution for Total Knee Arthroplasty
was launched in seven key markets since 2021
and has over 30.000 procedures completed.
The solution will be rolled out across Europe
during 2023 and 2024.
Studies showed that robotic-assisted TKA is
associated with improved patient outcomes,
reduced length of stay and reduced resource
utilization, both in inpatient settings and over
the 90 days episode of care. Overall, these
results can help reduce costs associated to
robotic-assisted TKA18,19. By 2027, roboticassisted total joint procedures are anticipated
to grow by more than 25%20.
For more information on the VELYS™
Robotic-Assisted Solution visit:
https://www.jnjmedtech.com/en-EMEA/
products/velys-robotic-assisted-solution
For more information on the ATTUNE™
Knee visit:
https://www.jnjmedtech.com/en-EMEA/
product/attune-knee-system
*
**
Comprising the surgery, orthopedics,
vision and interventional solutions
businesses within Johnson & Johnson’s
MedTech segment.
DePuy Synthes represents the products
and services of DePuy Synthes Sales, Inc.,
and its af昀椀liates.
References:
1 DePuy Synthes User Experience Evaluation
of the VELYSTM Robotic‐Assisted Solution
for Total Knee. July 2020.Windchill
#103744839 Page: 1 Paragraph: 4 Line: 1‐3
2 Doan, G.W., et al., Image‐Free Robotic‐
Assisted Total Knee Arthroplasty Improves
Implant Alignment Accuracy: A Cadaveric
Study. J Arthroplasty, 2022. 37(4): p. 795‐
801. Page: 1 Paragraph: 4 Line: 1‐3
3 Clatworthy, M., Patient‐Speci昀椀c TKA with
the VELYSTM Robotic‐ Assisted Solution.
Surg Technol Int, 2022. 40. Page: 1
Paragraph: 3 Line: 4‐5
4 Cool CL, Jacofsky DJ, Seeger KA, Sodhi N,
Mont MA. A 90‐day episode‐of‐care cost
analysis of robotic‐arm assisted total knee
arthroplasty. J Comp Eff Res. 2019;8(5):327‐
336
5 Pierce J, Needham K, Adams C, Coppolecchia
A, Lavernia C. Robotic arm‐assisted knee
surgery: an economic analysis. Am J Manag
Care. 2020;26(7):e205‐e210
6 Kayani B, Konan S, Tahmassebi J, Pietrzak
JRT, Haddad FS. Robotic‐arm assisted
total knee arthroplasty is associated
with improved early functional recovery
and reduced time to hospital discharge
compared with conventional jig‐based total
knee arthroplasty: a prospective cohort
study. Bone Joint J. 2018;100‐B(7):930‐938
7 Premier HOPD 2018‐ 2020 Q1 (December
2020). Internal Report. Pg. 1, Results table,
2nd row.
8 Courtis et al. Assessment Of Soft Tissue
Following Use Of A Novel Concept For
Robotic‐assisted Total Knee; ORS 2021
Annual Meeting Paper No. 1085. Page: 1
Paragraph: 6 Line: 1‐11
**** Dr. Vandekerckhove, Prof. Johannes Stöve
and Dr. Stefan Preiss are paid consultants
of DePuy Synthes Sales, Inc.
9 Hamilton, W. G., et al. (2021). “Comparison
of Existing and New Total Knee Arthroplasty
Implant
Systems
From
the
Same
Manufacturer: A Prospective, Multicenter
Study.” J Am Acad Orthop Surg Glob Res
Rev 5(12).
Dr. Lukas Becker is not a paid consultant of
DePuy Synthes Sales, Inc.
10 Fisher D, Parkin D. Optimizing the value
of your patients’ TKA: how to leverage
*** Martyn Inwood is an employee of Medical
Device Business Services, Inc.
Find out more 02921 680068 • e-mail admin@lawrand.com
Issue 397
15 Calliess T, Bauer K, Stukenborg‐Colsman C,
Windhagen H, et al. PSI kinematic versus
non PSI mechanical alignment in total knee
arthroplasty: a prospective, randomized
study. Knee Surg Sports Traumatol
Arthrosc. 2016;DOI 10.1007/s00167‐016‐
4136‐8.
16 Dossett HG, Estrada NA, Swartz GJ, LeFevre
GW, et al. A randomised controlled trial
of kinematically and mechanically aligned
total knee replacements. Bone Joint J.
2014;907‐913.
17 Clatworthy, M., Outcome & Survival Analysis
of Conventional Measured Resection,
Neutral Clinical Outcome – Product related
Orthopeadics Total knee replacement ‐
昀氀exed position N/A Claims Submission
Form Item #: 180035‐220627 Approved
For: EMEA ‐ Regional Only, United States
Tech File Number: N/A and mechanically
aligned total knee replacements. Bone
Joint J. 2014;907‐913. Page: 1 Paragraph:
3 Line: 1‐3 4. Clatworthy, M., Outcome &
Survival Analysis of Conventional Measured
Resection, Neutral Alignment Attune TKA
vs CAS Anatomic Tibia, Balanced Femur,
Constitutional Alignment Attune TKA.
Orthopaedic Journal of Sports Medicine,
2017. 5(5_suppl5): p. 2325967117S0015.
Page: 1 Paragraph: 3 Line: 1‐7 Alignment
Attune TKA vs CAS Anatomic Tibia,
Balanced Femur, Constitutional Alignment
Attune TKA. Orthopaedic Journal of
Sports Medicine, 2017. 5(5_suppl5): p.
2325967117S0015.
18 Kayani B, Konan S, Tahmassebi J, Pietrzak
JRT, Haddad FS. Robotic‐arm assisted
total knee arthroplasty is associated
with improved early functional recovery
and reduced time to hospital discharge
compared with conventional jig‐based total
knee arthroplasty: a prospective cohort
study. Bone Joint J. 2018;100‐B(7):930‐938
19 Stauss, R., Savov, P., Tuecking, LR. et al.
Robotic‐assisted TKA reduces surgery
duration, length of stay and 90‐day
complication rate of complex TKA to the
level of noncomplex TKA. Arch Orthop
Trauma Surg (2022).
20 Millennium
Research
Group,
Inc.
Orthopaedic Surgical Robotic Devices.
2018; M360SU0001.
October
2023
29