Stelrad Specification Book March 2024 - Catalog - Page 49
CLASSIC COLUMN VERTICAL
50
(75/65/20ºC)
Height
mm
Length
mm
Elements
Columns
Stelrad
UIN
Watts
Heat output
1800
352
7
2
163054
868
2962
444
9
2
163055
1116
3809
2000
352
7
2
163056
966
3297
444
9
2
163057
1242
4239
2500
352
7
2
163058
1197
4085
444
9
2
163059
1539
5253
Btu/hr
t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20ºC. If you have a low temperature
heat source you may wish to consider t40 or t30 output (see your installer or system designer or download from www.stelrad.com).
Due to production tolerances, the length of the product and therefore the tap centres could contain a variation of +/- 1.5% of the overall stated length.
For EN442 data, technical and installation information please visit our website: www.stelrad.com and search product downloads.
For systems not operating at DeltaT 50 the correction factors table on page 98 should be applied.
COLOUR OPTIONS
Comes in White as standard (RAL 9016). Please refer to page 103 for colour options.
All colour radiators have up to an 8 week lead time, and when a coloured radiator or
radiators have been ordered they cannot be cancelled or returned.
For more information on colour radiator prices please contact your local merchant.
BAR
WORKING
PRESSURE
49