EMEA Catalog EN 2019 - Catalog - Page 232
Volume fume extraction
MG 130
Fume extraction unit MG 130
100 W
LOW
SOUND
LEVEL
< 52 db (A)
TECHNICAL DATA
Order No. 130- 10 00- ESDN
Unit purifies air up to 2 workplaces
100–240 power supply for global use
Filter alarm and 3 steps speed control
Small foot print design
The fume extraction unit MG 130 is easy to install and operate.
Is supplied complete ready to place close to the workbench.
Max. capacity
Dimensions L x W x H (Inches)
Dimensions L x W x H (mm)
Weight (approx.) in kg
Voltage
Power
Noise level (distance 1 m) dB(A)
Max. blower vacuum (Pa)
Capacity m³/h
Pre-filter
Compact filter
ESD-safe
Scope of supply
Order No.
130-2000-ESDN
130-2010
232
Filtration
Model
MG 130 Unit
Compact filter MG
130
Fine dust filter F7 MG
130
1–2 workstations
18,11 x 8,26 x 19,68
460 x 210 x 500
11
100 - 240 V, 50/60 Hz
100 W
< 52
2.300
140
Pre filter mat class F7
Particle filter H13, Wide
band gas filter (50 %
Active carbon + 50 %
Chemisorb)
.
Description
MG 130 Unit
Particle filter H13 and wide band gas filter, Standard
Fine dust filter F7 for MG 130