iM3 Catalogue - USA - Flipbook - Page 77
iM3 | The Global Name in Veterinary Dentistry
42-12 Ultrasonic Scaler
Faster, easier to use, quieter;
less tooth damage. In a class of its own
compared to anything else!
42-12 USER UTAH, USA
Unlike other ultrasonic tooth scalers that use a “jack hammer”
approach to tooth scaling, the 42-12 adopts a more gentle
technique with its revolutionary rotational tip movement, and
ultrasonic removal of the plaque and calculus.
The 42-12 rapidly removes heavy calculus deposits from all tooth
surfaces and is safe to use in periodontal pockets up to 13 mm deep.
The 42-12 achieves a highly polished finish on the tooth with less
enamel damage by using an exceptionally high ultrasonic
frequency of 42,000 Hz, coupled with an extremely low amplitude
of the titanium scaler tip’s circular movement of 0.02 mm.
Power is permanently set at a high 42,000 Hz frequency (cycles)
yet is safe to use in periodontal pockets up to 13 mm deep. No
other veterinary ultrasonic scaler can do this safely because
they produce too much heat.
Lightweight handpiece with finger on/off control right where
you need it, eliminating need for a foot control.
The rotational tip movement and high ultrasonic frequency
create a fine coolant mist which is adjustable.
Rapidly removes plaque and calculus from all tooth surfaces,
while using a lighter touch on the enamel than required of
other ultrasonic scalers.
Unit supplied with universal and perio titanium tips and
spare ferrite rod.
Titanium tips last three to four times longer than stainless
steel scaler tips.
SCALERS
Lightweight handpiece
with finger on/off control
Cat. Code
O4212
Handpiece and tips are autoclavable.
iM3 42-12 Ferrite Rod and Scaler Tip Insert
1. Ferrite Rod
O1291
For the iM3 42-12 Scaler Tip Insert
1
2
3
4
5
2. Universal Tip
O0809
3. Perio Tip
O0806
4. Beaver Tail Tip
O0805
This tip is used for gross debridement of calculus
5. Thinline straight tip
O0802
Ideal for felines and small mouths
42-12 Tip Holder
O1651
Safely and securely holds up to three 42-12 scaler tips.
Use the 42-12 Ultrasonic Scaler Tip Wear Guide to check
whether your ultrasonic scaler tip needs to be replaced.
1. Tip wear will significantly reduce scaler performance as it will
alter the ultrasonic frequency.
2. The ferrite rod must be tight – a loose or broken rod will cause
poor or no vibration.
3. A correctly functioning tip used on a power setting of 3-4 lights
will produce a coolant mist around the tip.
www.im3vet.com